VERIFICATION OF THE EMISSIVITY VALUE OF SELECTED REFERENCE PAINTS FOR NON-CONTACT TEMPERATURE MEASUREMENT

1 NĚMEC Tomáš
Co-authors:
1 KOLAŘÍKOVÁ Marie 1 KOLAŘÍK Ladislav 2 SOVA Jan
Institutions:
1 Czech Technical University in Prague, Faculty of Mechanical Engineering, Prague, Czech Republic, EU, Tomas.Nemec@fs.cvut.cz
2 HED Partner, s.r.o, Czech Republic, EU
Conference:
32nd International Conference on Metallurgy and Materials, Orea Congress Hotel Brno, Czech Republic, EU, May 17 - 19, 2023
Proceedings:
Proceedings 32nd International Conference on Metallurgy and Materials
Pages:
359-363
ISBN:
978-80-88365-12-9
ISSN:
2694-9296
Published:
8th January 2024
Proceedings of the conference were published in Web of Science.
Metrics:
301 views / 363 downloads
Abstract

The paper deals with the issue of temperature dependence of emissivity in reference paints for surface homogenization during non-contact temperature measurement using infrared camera. Two different paints for high-temperature applications are under investigation. Emissivity is measured with a FLIR E95 infrared camera using procedures according to ČSN EN ISO 18434-1 standard. The obtained results are important especially for practical applications in which it is necessary to quantitatively measure the variable surface temperature on objects for which the homogeneity of the surface cannot be unequivocally guaranteed.

Keywords: Emissivity, Reference Paint, Infrared Camera

© This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Scroll to Top